2023-2024_総合研究院パンフレット(英文)
9/38

ExampleofAvailableFacilities/EquipmentCone Calorimeter Testing Device (ISO 5660)This device is used to examine ignitability and the exothermal properties of construction materials using thermal radiation. A test object is placed under the conical-shape electric heater, which controls the thermal radiation to the object, and a pilot flame, is applied to the object 10mm from its surface. The ignition time and the heat release rate can be measured per thermal radiation that can be set in the range of 0 to 50 kW//m2.Calorimetry Hoods (5 m × 5 m)This unit is used to analyze the burning characteristics of furniture and equipment in a room by burning them and collecting the burning gas. The duct is equipped with devices for flow measurement and sampling. The design heat release rate is 2 MW at maximum, and the smoke suction power is 600 m3/min at maximum. A movable unit (4 m × 4 m) is also available.Structural Fire Testing Furnace (Medium scale)This unit is used to evaluate the fire-resistive performance of various structural members such as columns, beams, floors and walls. The unit can control the heat to the standard heating temperature and furnace pressure set by ISO 834.The heating furnace, with dimensions of 1.5 m (W) × 1.5 m (D) × 1.5 m (H), can also provide immediate heating.FTIR Gas AnalyzerThis unit is designed to be connected to the combustion and smoke generation tester and enables high-speed and continuous analysis of combustion gas. A measured value can be updated at short intervals (five to ten seconds). This unit specializes in measuring certain types of gas that is result from combustion in fire.Full-Scale Compartment for Fire Experiment(with Water Pump)This fire compartment is 6 m (W) × 6 m (D) × 2.7 m (H) in actual size, and the sprinkler system can be attached to the ceiling. The compartment is mainly used to evaluate the fire extinguishing performance of sprinkler systems and also has used for experiments on smoke movement during sprinkler system activation.Structural Fire Testing Furnace (Large scale, for Walls)This unit is used to evaluate the fire-resistive performance of an exterior wall under fire and can control the heat to the standard heating temperature and furnace pressure set by ISO 834. There are 20 burners on the lateral side, and this can heat up to a 3.5 m × 3.5 m area. The unit is also suitable for performing heat tests.ICAL Testing Unit (Heat Radiation Panel)This unit is designed to elucidate the burning behavior of combustible materials under the condition where a certain heat flux was given through radiative heat transfer. The unit can also be used to investigate the behavior of members exposed to radiative heat. The panel heater has a heating area of 1.75 m (W) × 1.38 m (H). Members can be exposed experimentally to surface temperatures up to 950 and a heat flux of 50 kW/m2.Room Corner Testing Unit (ISO 9705)This unit is comprised of a space of 2.4 m (W) × 3.6 m (D) × 2.4 m (H) (approximately, the size of a 6-tatamimat room) and an opening 0.8 m (W) × 2 m (H). It can be used to recreate a fire in a room with furniture and dry walls, which can be developed into a fully developed fire.In addition, flashover experiments can be performed with this unit by recreating fires that spread to entire rooms in a short time period, and then combustible gas concentration and temperature distribution data can be collected. The development of the fire can be captured by video camera.Multiple Full-scale FurnaceThis device is used to measure the fire-resistive duration of horizontal materials of buildings including beams, floors and roofs by using the standard heating test (ISO834). Fire-resistive performance of any kind of horizontal materials can be evaluated by the heating test using this device. Put a full-scale model of 3 m (W) × 4 m (D) on the top the heater like covering it and then turn on the burner to heat the model from beneath.09

元のページ  ../index.html#9

このブックを見る